EICR testing · Greater London

Every borough.
Every front
door.

Fixed-price electrical safety reports from Hillingdon to Havering, for landlords, letting agents, homeowners and businesses. We handle the London parts too: parking, porters, keys and licence paperwork.

Check your postcode

We cover every London postcode district, inner and outer.

33
London boroughs covered
"Keys, porters and parking sorted before anyone sets off."
Our access promise
33
London boroughs
C1
Made safe on the spot
CCZ
Congestion Charge included
BS 7671
Tested to the Wiring Regulations
Fixed
Price in writing
ID
Shown on arrival
48h
Report turnaround
£0
Hidden extras
What is an EICR?

A health check for the wiring you can't see.

An Electrical Installation Condition Report (EICR) is a formal inspection and test of a property’s fixed electrical installation: the consumer unit, circuits, sockets, switches, light fittings and everything permanently wired in. A qualified electrician checks it against BS 7671, the UK Wiring Regulations, and records anything unsafe or out of date.

In London it’s a legal requirement for most private landlords every five years, a licence condition in many boroughs, and something buyers, insurers and managing agents increasingly ask for. The report gives an overall result, satisfactory or unsatisfactory, with each issue coded by urgency.

Maximum gap between inspections for rented homes
0 yrs
To give tenants a copy and complete any repairs
0 days
2–5 hrs
Typical time on site for a London flat or house
Maximum council penalty per breach for landlords
£ 0 k
London, 33 boroughs
Scroll →
Highlighted
Other boroughs
Selected
01 / 06

All 33 boroughs, one fixed price.

All 32 London boroughs plus the City of London. The same BS 7671 inspection, the same detailed report and the same fixed-price promise, whether it’s a studio in Shoreditch or a family home in Bexley.

33
Boroughs covered
48h
Report turnaround
£75
From, fixed
£0
Surprise add-ons
02 / 06

Inner London: houses split into flats.

Victorian and Edwardian terraces converted into two to four flats, mansion blocks, and flats above shops. Expect shared supplies, landlord circuits in communal hallways, and wiring of several different ages, sometimes in the same room.

03 / 06

Outer London: semis, maisonettes & HMOs.

Interwar semis, purpose-built maisonettes and larger family homes, many now let as HMOs. Usually easier parking and access, but more circuits, outbuildings and garden supplies to test.

"Garden circuits, outbuildings and every HMO room tested in one visit."
Included as standard
04 / 06

Central zone? It's in the price.

Jobs inside the Congestion Charge zone, which covers the City and Westminster and parts of the neighbouring boroughs, and in controlled parking zones across inner London, need a little more planning. Any charge or parking cost is included in your fixed quote, never added afterwards.

05 / 06

Borough licensing, ready to submit.

Many London councils run mandatory, additional or selective licensing schemes for rented homes, and most ask for a valid EICR with the application. Schemes change, so always check your own council’s current rules. We’ll make sure the report covers what they ask for.

06 / 06

Now, pick your borough.

Tap any tile on the map to see what to expect there, then book with your borough already filled in.

Inner London

Hackney

Victorian conversions, ex-council blocks and a growing number of new-builds. Controlled parking is common, so we plan permits before the visit.

What we test

Eight things every London EICR checks.

The inspection combines a visual check with live and dead testing of every accessible circuit. Here’s what the electrician looks at, and why each part matters.

01

Consumer unit

Condition, suitability and labelling of the fuse board, and whether every circuit has the right protective device.

02

Earthing & bonding

The main earth and the bonding to gas and water pipes. It’s what stops metalwork becoming live during a fault.

03

RCD protection

Trip times and test-button operation of the residual current devices that cut power in milliseconds.

04

Sockets & switches

A sample opened up for loose connections and scorching, plus checks for damage and correct polarity.

05

Lighting circuits

Earth continuity to fittings, especially in older London flats where lighting circuits often lack an earth.

06

Wiring condition

Insulation resistance on every circuit. It reveals ageing, damaged or rodent-chewed cables you can’t see.

07

Bathrooms

Fittings rated for their zone, shower circuits and supplementary protection where water and electricity meet.

08

Outside & outbuildings

Garden sockets, external lights, garages and sheds. Weather makes these the fastest-deteriorating circuits.

Reading the result

Four codes, one clear next step.

Every observation is given a code. Any C1, C2 or FI makes the overall report unsatisfactory. A C3 on its own does not.

C1

Danger present

Immediate risk of injury, such as exposed live parts. Made safe before the electrician leaves.

Unsatisfactory
C2

Potentially dangerous

Not dangerous yet, but would be under fault conditions, e.g. missing earthing. Urgent repair.

Unsatisfactory
FI

Further investigation

Something couldn’t be fully verified during the visit and needs investigating promptly.

Unsatisfactory
C3

Improvement recommended

Doesn’t meet the latest standard but is safe. Optional, and doesn’t fail the report.

Satisfactory
48h
From visit to full report

Licence-ready reports, with schedules and remedial certificates attached, so applications go in first time.

A
For letting agentsLicence applications

We arrange tenant notice, keys, porters and permits before the visit, so nobody is left waiting at the door.

L
For landlordsAccess arranged

The price you are quoted in writing is the price you pay, with Congestion Charge and parking included.

H
For homeownersFixed price
Who we work with

Built around how London rents, buys and works.

The inspection standard is the same for everyone. The paperwork, deadlines and access arrangements aren’t, so we plan around yours.

01

Private landlords

Single lets and small portfolios that need to stay compliant without chasing tradespeople.

Single lets & portfolios
02

Letting & managing agents

Bulk bookings across boroughs, with consistent reports and one point of contact.

One point of contact
03

HMO operators

Room-by-room testing, communal areas and landlord supplies, ready for licensing.

Mandatory, additional & selective schemes
04

Homeowners & buyers

Peace of mind on an older London home, or evidence before you buy or sell.

Ideal before exchange
05

Freeholders & blocks

Landlord supplies, communal lighting, door entry and risers in purpose-built and mansion blocks.

Separate report per supply
06

Shops, offices & cafés

Small commercial premises tested before opening or after close, so trading isn’t interrupted.

5-year interval for most premises
Property types

Six London homes, six different jobs.

The age and layout of the building decide how long testing takes and what’s likely to come up. Choose yours.

c.1880–1910

Victorian conversion flat

An old terrace split into two to four flats. Expect shared supplies, wiring of different ages, and the occasional borrowed neutral between floors.

Typical
2–3 hours · 5–8 circuits
Watch for
Shared supplies, older lighting circuits
Access
Tenant or agent keys, shared front door
c.1890–1935

Mansion block flat

Solid walls, long cable runs and communal risers. Access to the meter cupboard and the landlord’s board usually goes through the porter.

Typical
2–4 hours · 6–10 circuits
Watch for
Older risers, unlabelled boards
Access
Porter / managing agent booked ahead
c.1950–1980

Ex-local authority flat

Often an older consumer unit, with communal electrics controlled by the council or freeholder. The report covers the flat’s own installation.

Typical
2–3 hours · 5–7 circuits
Watch for
Older boards, missing RCD protection
Access
Tenant, concierge or key safe
2000s–today

New-build apartment

Usually a modern RCBO board and quick to test. Access tends to go through building management, and the board is often in a utility cupboard.

Typical
1.5–2.5 hours · 6–9 circuits
Watch for
Underfloor heating, smart systems
Access
Building management sign-in
Mixed use

Flat above a shop

Separate commercial and residential supplies, which are sometimes linked. We confirm exactly what feeds the flat so the report covers the right installation.

Typical
2–3 hours · 5–8 circuits
Watch for
Shared or linked supplies
Access
Side door / shop hours
5+ rooms

HMO / shared house

Room by room, plus communal areas, kitchen circuits and any landlord supplies. Paperwork ready for your borough licence application.

Typical
Half to full day · 10–20 circuits
Watch for
Extra sockets added by tenants, kitchen loads
Access
Notice to every tenant arranged
For London landlords

England's rules, plus your borough's.

Rented homes in London fall under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Many boroughs then add licensing on top.

Every 5 years
Inspect & test the fixed installation
Or sooner, if the last report says so
Before move-in
Give new tenants a copy
Alongside the gas certificate and EPC
Within 28 days
Give existing tenants a copy
Of the date of the inspection
Within 28 days
Complete C1, C2 and FI work
Or the shorter period stated on the report
Within 7 days
Provide it to the council on request
Penalties of up to £30,000 per breach

Borough licensing, in brief

Licensing is set by each council, and schemes are introduced, renewed and expanded regularly. Here’s how the three types usually work. Always check your council’s current scheme before applying.

SchemeUsually coversEICR
Mandatory HMO5+ people, 2+ households, nationwideExpected with application
AdditionalSmaller HMOs in designated areasUsually required
SelectiveSingle-household lets in designated areasOften required

General guidance only. Requirements vary by council.

London prices

Fixed before we book, charges included.

Priced by property size, which is a good guide to the circuit count. Your written price includes any Congestion Charge or parking cost.

Studio / 1-bed flatUp to ~6 circuits
£75–98.99
2-bed flat or houseUp to ~8 circuits
£98.99
3-bed flat or houseUp to ~10 circuits
£98.99
4–5 bed houseUp to ~16 circuits · 2 boards
£109.99–149.99
HMO & shared houseRooms, communal & landlord supply
£159.99+
Shops, offices & blocksCommercial & communal
£149.99+
FIXED-PRICE PROMISE · NO HIDDEN EXTRAS ·
£

In every London price

Prices are a guide for typical properties and are confirmed in writing before booking. If we find more circuits than quoted, we’ll tell you before doing any extra work.

Schedule of test results
p.4
Schedule of inspections
p.3
EICR · BS 7671
p.1

Electrical Installation Condition Report

Address
Flat 2, N16
Circuits tested
8 of 8
Earthing
TN-C-S
Next inspection
5 years
Satisfactory
What you receive

A full report, not a one-page certificate.

Some quotes are cheap because the paperwork is thin. A proper EICR runs to several pages, and every page matters to councils, insurers and the next electrician.

01
Summary & overall result

Satisfactory or unsatisfactory, the extent of the inspection, and any limitations.

02
Coded observations

Every C1, C2, FI and C3 with its location and a plain-English description.

03
Schedule of inspections

The full checklist of everything examined, item by item.

04
Schedule of test results

Readings for every circuit: continuity, insulation resistance, loop impedance and RCD times.

How it works

Planned so it happens first time.

Most missed appointments in London come down to keys, parking or porters. We sort all three before anyone sets off.

1

Postcode & property

Tell us the address, size and who holds the keys, online or by phone.

2 minutes
2

Fixed price, in writing

Including any charge-zone or parking cost, with dates that suit your tenant or agent.

Same day
3

Access confirmed

Tenant notice, key collection, porter booking and visitor permits, confirmed in advance. You’ll get a text when we’re on the way.

Before visit
4

Inspection & testing

A qualified electrician tests every accessible circuit, with only short power-offs. Any C1 danger is made safe on the spot.

2–5 hours
✓

Report delivered

A PDF ready to share with your tenants, agent or council, plus an itemised repair quote if needed.

Within 48h
EICR Testing London
ID · On arrival

Your inspector

Qualified & insured
Quals
C&G 2391 · 18th Ed.
Scheme
Competent-person
Checks
Photo ID on arrival
Verify: 020 3386 1854
Who turns up

A qualified inspector, not a general handyman.

The 2020 regulations say the inspector must be “qualified and competent”. Here’s what that means when someone arrives at your London property.

Inspection & testing qualified

City & Guilds 2391 (or equivalent) and current BS 7671.

Scheme registered

Check the electrician on the scheme’s public register.

ID on arrival

Photo ID, plus a text with their name before they arrive.

Calibrated test kit

Instrument serials and calibration recorded on the report.

Respectful of tenants

Shoe covers, dust sheets and power restored before leaving.

Insured

Public liability and professional indemnity cover.

Communal lighting, door entry and landlord supplies tested out of hours, with a separate report for each supply.

B
For block managersCommunal areas

An EICR before exchange gives you a clear picture of the wiring, and a quote for anything that needs work.

P
For buyersBefore exchange

Early or late slots, so shops, offices and cafés are tested without interrupting trading.

S
For businessesOutside trading hours
Coverage

Every London postcode district.

From EC1 to RM14. If your postcode starts with one of these, we cover it at our standard London prices.

CentralEC · WC

EC1 EC2 EC3 EC4 WC1 WC2

NorthN

N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 N13 N14 N15 N16 N17 N18 N19 N20 N21 N22

North WestNW

NW1 NW2 NW3 NW4 NW5 NW6 NW7 NW8 NW9 NW10 NW11

EastE

E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E20

WestW

W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14

South WestSW

SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10 SW11 SW12 SW13 SW14 SW15 SW16 SW17 SW18 SW19 SW20

South EastSE

SE1 SE2 SE3 SE4 SE5 SE6 SE7 SE8 SE9 SE10 SE11 SE12 SE13 SE14 SE15 SE16 SE17 SE18 SE19 SE20 SE21 SE22 SE23 SE24 SE25 SE26 SE27 SE28

Outer London11 areas

BR · CR · DA · EN · HA · IG · KT · RM · SM · TW · UB

Questions

London EICR, answered.

Still got a question?

Speak to the London team. We’ll give you a straight answer and a fixed price.

Yes, all 32 London boroughs and the City of London, inner and outer. Use the postcode checker at the top of the page, or tap your borough on the map.

A studio is £75, a one- to three-bedroom flat or house is £98.99, and a four- or five-bed house is £109.99–£149.99. Larger homes are £149.99 for six bedrooms, £199.99 for seven and £219.99 for eight. Commercial EICRs start from £149.99 for up to 12 circuits, or £269.99 for 12–36 circuits. Your price is fixed in writing and includes any Congestion Charge or parking cost.

Most London flats take two to three hours, and houses three to five. HMOs can take half a day or more depending on the number of rooms and circuits.

No. Power is switched off for short periods while each circuit is tested. We recommend tenants back up computers and keep fridge and freezer doors closed during the visit.

Most London boroughs running mandatory, additional or selective licensing ask for a valid EICR, either with the application or as a licence condition. Requirements vary and change, so check your council’s current scheme. Our reports are licence-ready.

Yes. We can collect keys from you or your agent, use a key safe, or arrange access with a porter or building manager. Your tenant still needs written notice of the visit.

Your EICR covers your flat, from its meter or board onwards. Communal lighting, door entry and landlord supplies are usually the freeholder’s or managing agent’s responsibility, and we can test them under a separate report.

For rented homes, up to five years, or less if the inspector recommends it. For owner-occupied homes, a 10-year interval or a change of occupancy is the usual guidance.

You’ll get an itemised quote for any C1, C2 or FI items. Landlords must complete the work within 28 days, or sooner if the report says so, then send written confirmation to the tenant and the council. You’re free to use any qualified electrician for the repairs.

No. An EICR covers the fixed wiring. PAT testing covers plug-in appliances. Landlords who supply appliances often book both, and we can do them in the same visit. PAT testing starts from £49.99 for up to 10 appliances.

Book

Your borough, your fixed price.

Send the postcode and a few details. We’ll reply with a fixed price and dates, usually the same working day.

48h
From visit to full report
Get your fixed price
Replying today
🔒 Your details are never shared