Every borough.
Every front
door.
Fixed-price electrical safety reports from Hillingdon to Havering, for landlords, letting agents, homeowners and businesses. We handle the London parts too: parking, porters, keys and licence paperwork.
We cover every London postcode district, inner and outer.
- From £75, fixed
- Congestion Charge included
- Report within 48h
- Licence-ready
A health check for the wiring you can't see.
An Electrical Installation Condition Report (EICR) is a formal inspection and test of a property’s fixed electrical installation: the consumer unit, circuits, sockets, switches, light fittings and everything permanently wired in. A qualified electrician checks it against BS 7671, the UK Wiring Regulations, and records anything unsafe or out of date.
In London it’s a legal requirement for most private landlords every five years, a licence condition in many boroughs, and something buyers, insurers and managing agents increasingly ask for. The report gives an overall result, satisfactory or unsatisfactory, with each issue coded by urgency.
Inner London: houses split into flats.
Victorian and Edwardian terraces converted into two to four flats, mansion blocks, and flats above shops. Expect shared supplies, landlord circuits in communal hallways, and wiring of several different ages, sometimes in the same room.
- Each flat's supply traced to the right meter
- Landlord's communal supply reported separately
- Porter and managing-agent access arranged
Outer London: semis, maisonettes & HMOs.
Interwar semis, purpose-built maisonettes and larger family homes, many now let as HMOs. Usually easier parking and access, but more circuits, outbuildings and garden supplies to test.
- Garages, sheds & garden circuits included
- HMO room-by-room detail for licensing
- Earlier slots where parking is simple
Central zone? It's in the price.
Jobs inside the Congestion Charge zone, which covers the City and Westminster and parts of the neighbouring boroughs, and in controlled parking zones across inner London, need a little more planning. Any charge or parking cost is included in your fixed quote, never added afterwards.
- Charge & parking shown up front
- Visitor permits arranged with you
- Loading-bay timing for mansion blocks
Borough licensing, ready to submit.
Many London councils run mandatory, additional or selective licensing schemes for rented homes, and most ask for a valid EICR with the application. Schemes change, so always check your own council’s current rules. We’ll make sure the report covers what they ask for.
- Fully signed EICR with schedules
- HMO rooms & communal areas covered
- Remedial certificates attached if needed
Now, pick your borough.
Tap any tile on the map to see what to expect there, then book with your borough already filled in.
Hackney
Victorian conversions, ex-council blocks and a growing number of new-builds. Controlled parking is common, so we plan permits before the visit.
Eight things every London EICR checks.
The inspection combines a visual check with live and dead testing of every accessible circuit. Here’s what the electrician looks at, and why each part matters.
Consumer unit
Condition, suitability and labelling of the fuse board, and whether every circuit has the right protective device.
Earthing & bonding
The main earth and the bonding to gas and water pipes. It’s what stops metalwork becoming live during a fault.
RCD protection
Trip times and test-button operation of the residual current devices that cut power in milliseconds.
Sockets & switches
A sample opened up for loose connections and scorching, plus checks for damage and correct polarity.
Lighting circuits
Earth continuity to fittings, especially in older London flats where lighting circuits often lack an earth.
Wiring condition
Insulation resistance on every circuit. It reveals ageing, damaged or rodent-chewed cables you can’t see.
Bathrooms
Fittings rated for their zone, shower circuits and supplementary protection where water and electricity meet.
Outside & outbuildings
Garden sockets, external lights, garages and sheds. Weather makes these the fastest-deteriorating circuits.
Four codes, one clear next step.
Every observation is given a code. Any C1, C2 or FI makes the overall report unsatisfactory. A C3 on its own does not.
Danger present
Immediate risk of injury, such as exposed live parts. Made safe before the electrician leaves.
Potentially dangerous
Not dangerous yet, but would be under fault conditions, e.g. missing earthing. Urgent repair.
Further investigation
Something couldn’t be fully verified during the visit and needs investigating promptly.
Improvement recommended
Doesn’t meet the latest standard but is safe. Optional, and doesn’t fail the report.
Licence-ready reports, with schedules and remedial certificates attached, so applications go in first time.
We arrange tenant notice, keys, porters and permits before the visit, so nobody is left waiting at the door.
The price you are quoted in writing is the price you pay, with Congestion Charge and parking included.
Built around how London rents, buys and works.
The inspection standard is the same for everyone. The paperwork, deadlines and access arrangements aren’t, so we plan around yours.
Private landlords
Single lets and small portfolios that need to stay compliant without chasing tradespeople.
- 5-year renewal reminders
- Tenant notice handled
- PDF ready to forward
Letting & managing agents
Bulk bookings across boroughs, with consistent reports and one point of contact.
- Portfolio scheduling
- Key collection from branch
- Monthly invoicing
HMO operators
Room-by-room testing, communal areas and landlord supplies, ready for licensing.
- Licence-ready format
- Every tenant notified
- Remedials certified
Homeowners & buyers
Peace of mind on an older London home, or evidence before you buy or sell.
- Pre-purchase checks
- Plain-English summary
- Repair quotes if needed
Freeholders & blocks
Landlord supplies, communal lighting, door entry and risers in purpose-built and mansion blocks.
- Communal-areas report
- Porter liaison
- Out-of-hours available
Shops, offices & cafés
Small commercial premises tested before opening or after close, so trading isn’t interrupted.
- Early or late slots
- Board-by-board testing
- Insurer-ready report
Six London homes, six different jobs.
The age and layout of the building decide how long testing takes and what’s likely to come up. Choose yours.
Victorian conversion flat
An old terrace split into two to four flats. Expect shared supplies, wiring of different ages, and the occasional borrowed neutral between floors.
- Typical
- 2–3 hours · 5–8 circuits
- Watch for
- Shared supplies, older lighting circuits
- Access
- Tenant or agent keys, shared front door
Mansion block flat
Solid walls, long cable runs and communal risers. Access to the meter cupboard and the landlord’s board usually goes through the porter.
- Typical
- 2–4 hours · 6–10 circuits
- Watch for
- Older risers, unlabelled boards
- Access
- Porter / managing agent booked ahead
Ex-local authority flat
Often an older consumer unit, with communal electrics controlled by the council or freeholder. The report covers the flat’s own installation.
- Typical
- 2–3 hours · 5–7 circuits
- Watch for
- Older boards, missing RCD protection
- Access
- Tenant, concierge or key safe
New-build apartment
Usually a modern RCBO board and quick to test. Access tends to go through building management, and the board is often in a utility cupboard.
- Typical
- 1.5–2.5 hours · 6–9 circuits
- Watch for
- Underfloor heating, smart systems
- Access
- Building management sign-in
Flat above a shop
Separate commercial and residential supplies, which are sometimes linked. We confirm exactly what feeds the flat so the report covers the right installation.
- Typical
- 2–3 hours · 5–8 circuits
- Watch for
- Shared or linked supplies
- Access
- Side door / shop hours
HMO / shared house
Room by room, plus communal areas, kitchen circuits and any landlord supplies. Paperwork ready for your borough licence application.
- Typical
- Half to full day · 10–20 circuits
- Watch for
- Extra sockets added by tenants, kitchen loads
- Access
- Notice to every tenant arranged
England's rules, plus your borough's.
Rented homes in London fall under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Many boroughs then add licensing on top.
Borough licensing, in brief
Licensing is set by each council, and schemes are introduced, renewed and expanded regularly. Here’s how the three types usually work. Always check your council’s current scheme before applying.
| Scheme | Usually covers | EICR |
|---|---|---|
| Mandatory HMO | 5+ people, 2+ households, nationwide | Expected with application |
| Additional | Smaller HMOs in designated areas | Usually required |
| Selective | Single-household lets in designated areas | Often required |
General guidance only. Requirements vary by council.
Fixed before we book, charges included.
Priced by property size, which is a good guide to the circuit count. Your written price includes any Congestion Charge or parking cost.
In every London price
- Full inspection & testing to BS 7671
- Tenant, agent or porter access arranged
- Congestion Charge & parking costs
- Digital report within 48 hours
- Itemised quote for any repairs
- Reminder before your renewal
Prices are a guide for typical properties and are confirmed in writing before booking. If we find more circuits than quoted, we’ll tell you before doing any extra work.
Electrical Installation Condition Report
A full report, not a one-page certificate.
Some quotes are cheap because the paperwork is thin. A proper EICR runs to several pages, and every page matters to councils, insurers and the next electrician.
Satisfactory or unsatisfactory, the extent of the inspection, and any limitations.
Every C1, C2, FI and C3 with its location and a plain-English description.
The full checklist of everything examined, item by item.
Readings for every circuit: continuity, insulation resistance, loop impedance and RCD times.
Planned so it happens first time.
Most missed appointments in London come down to keys, parking or porters. We sort all three before anyone sets off.
Postcode & property
Tell us the address, size and who holds the keys, online or by phone.
Fixed price, in writing
Including any charge-zone or parking cost, with dates that suit your tenant or agent.
Access confirmed
Tenant notice, key collection, porter booking and visitor permits, confirmed in advance. You’ll get a text when we’re on the way.
Inspection & testing
A qualified electrician tests every accessible circuit, with only short power-offs. Any C1 danger is made safe on the spot.
Report delivered
A PDF ready to share with your tenants, agent or council, plus an itemised repair quote if needed.
Your inspector
- Quals
- C&G 2391 · 18th Ed.
- Scheme
- Competent-person
- Checks
- Photo ID on arrival
A qualified inspector, not a general handyman.
The 2020 regulations say the inspector must be “qualified and competent”. Here’s what that means when someone arrives at your London property.
City & Guilds 2391 (or equivalent) and current BS 7671.
Check the electrician on the scheme’s public register.
Photo ID, plus a text with their name before they arrive.
Instrument serials and calibration recorded on the report.
Shoe covers, dust sheets and power restored before leaving.
Public liability and professional indemnity cover.
Communal lighting, door entry and landlord supplies tested out of hours, with a separate report for each supply.
An EICR before exchange gives you a clear picture of the wiring, and a quote for anything that needs work.
Early or late slots, so shops, offices and cafés are tested without interrupting trading.
Every London postcode district.
From EC1 to RM14. If your postcode starts with one of these, we cover it at our standard London prices.
CentralEC · WC
EC1 EC2 EC3 EC4 WC1 WC2
NorthN
N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 N12 N13 N14 N15 N16 N17 N18 N19 N20 N21 N22
North WestNW
NW1 NW2 NW3 NW4 NW5 NW6 NW7 NW8 NW9 NW10 NW11
EastE
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E20
WestW
W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14
South WestSW
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10 SW11 SW12 SW13 SW14 SW15 SW16 SW17 SW18 SW19 SW20
South EastSE
SE1 SE2 SE3 SE4 SE5 SE6 SE7 SE8 SE9 SE10 SE11 SE12 SE13 SE14 SE15 SE16 SE17 SE18 SE19 SE20 SE21 SE22 SE23 SE24 SE25 SE26 SE27 SE28
Outer London11 areas
BR · CR · DA · EN · HA · IG · KT · RM · SM · TW · UB
London EICR, answered.
Speak to the London team. We’ll give you a straight answer and a fixed price.
Do you cover all of London?
Yes, all 32 London boroughs and the City of London, inner and outer. Use the postcode checker at the top of the page, or tap your borough on the map.
How much does an EICR cost in London?
A studio is £75, a one- to three-bedroom flat or house is £98.99, and a four- or five-bed house is £109.99–£149.99. Larger homes are £149.99 for six bedrooms, £199.99 for seven and £219.99 for eight. Commercial EICRs start from £149.99 for up to 12 circuits, or £269.99 for 12–36 circuits. Your price is fixed in writing and includes any Congestion Charge or parking cost.
How long does an EICR take?
Most London flats take two to three hours, and houses three to five. HMOs can take half a day or more depending on the number of rooms and circuits.
Will the power be off all day?
No. Power is switched off for short periods while each circuit is tested. We recommend tenants back up computers and keep fridge and freezer doors closed during the visit.
Does my borough's licensing scheme need an EICR?
Most London boroughs running mandatory, additional or selective licensing ask for a valid EICR, either with the application or as a licence condition. Requirements vary and change, so check your council’s current scheme. Our reports are licence-ready.
Can you test while my tenant is at work?
Yes. We can collect keys from you or your agent, use a key safe, or arrange access with a porter or building manager. Your tenant still needs written notice of the visit.
Who tests the communal electrics in my block?
Your EICR covers your flat, from its meter or board onwards. Communal lighting, door entry and landlord supplies are usually the freeholder’s or managing agent’s responsibility, and we can test them under a separate report.
How long is an EICR valid?
For rented homes, up to five years, or less if the inspector recommends it. For owner-occupied homes, a 10-year interval or a change of occupancy is the usual guidance.
What if my London property fails?
You’ll get an itemised quote for any C1, C2 or FI items. Landlords must complete the work within 28 days, or sooner if the report says so, then send written confirmation to the tenant and the council. You’re free to use any qualified electrician for the repairs.
Is an EICR the same as a PAT test?
No. An EICR covers the fixed wiring. PAT testing covers plug-in appliances. Landlords who supply appliances often book both, and we can do them in the same visit. PAT testing starts from £49.99 for up to 10 appliances.
Your borough, your fixed price.
Send the postcode and a few details. We’ll reply with a fixed price and dates, usually the same working day.
- Price fixed in writing before booking
- Charge-zone & parking costs included
- Report within 48 hours
- Repairs quoted separately: your choice